8 CH EEG/EP System-8Channels EMG/EP System
For quantitative EMG recording, Evoked Potential(EP), Nerve conduction velocity (NCV) diagnostic examination for medical and research purpose.
Description
Key Features
(1)The amplifier and electrical stimulation module are integrated into the all-in-one main unit, resulting in a highly compact system structure that is ideal for use in clinical scenarios requiring mobile deployment.
(2) Digital isolation design and optimized anti-interference measures for clinical environments reduce the impact of power supply and environmental factors on signal acquisition.
(3) The system features a simple and clean interface design, facilitating easy installation and operation. It supports selection of various optional configurations based on application requirements to meet different types of neurophysiological examinations.
(4) Connects to a computer via a USB interface. The software supports mainstream Windows operating systems and can adapt to computer environments with different display sizes and resolutions.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Technical Specifications
|
A/D conversion rate |
24Bit
|
|
Scanning speed measurement error |
0.1~30000ms/div, error≤±10%
|
|
Sensitivity |
0.01μV/div-30000μV/div
|
|
Amplitude-frequency characteristic |
0.1Hz~10kHz; error -10%~+5%
|
|
CMRR |
≥120dB
|
|
Noise voltage |
≤0.4μVrms (20Hz, 2kHz)
|
|
Input impedance |
≥3000MΩ
|
|
Current intensity output range |
1~100mA
|
|
Stimulus frequency |
0.1Hz~50Hz
|
|
Stimulus width |
50-1000μs
|
Advantage
Advantage 1: Multi-Channel Synchronous Acquisition Under Portable ConditionsCompared with single-channel or low-channel portable devices, the multi-channel synchronous acquisition capability helps improve information integrity in routine clinical examinations and reduce the need for repeated tests.
Advantage 2: Synchronous Acquisition Improves Examination Efficiency and Consistency
Multi-channel synchronous acquisition allows clinicians to obtain information from multiple sites in a single examination, shortening examination time and simplifying the comparison and interpretation of results.
Advantage 3: Meets Routine and Selected Complex Clinical Application Needs
While supporting routine neurophysiological examinations, the device can be configured with multi-channel acquisition schemes based on actual application requirements to meet examination needs in different clinical scenarios.
Service & Support: Global Technical Assurance
We provide a comprehensive technical support and service system covering the full product lifecycle for the NCC System, including installation support, application training, and technical documentation support, to help users maintain stable operation of the device.
Partner Programs
1. Distributor Support Program
We provide global distribution partners with comprehensive sales collaterals, product training, and technical support, empowering them to conduct compliant promotion and application of the product in local markets.
2. Technical Training & Enablement
We offer product-specific application training and technical exchanges, supporting our partners in conducting product demonstrations and usage training activities across diverse markets worldwide.