Built on the clinically-proven Cynapse platform, the Cynapse Lite combines excellent signal acquisition with a streamlined, compact design. Renowned for its exceptional interference resistance, the system brings neurophysiology into the environment of the operating room.
With a software interface fully optimized for touchscreen interaction, Cynapse Lite ensures that your focus remains on the patient, not the equipment.
Description
The Cynapse Lite integrates three specialized modules, creating a comprehensive and stable monitoring system specifically engineered for ENT procedures. 4-channel and 8-channel options are available.
RLN (Recurrent Laryngeal Nerve) Monitoring
Maximize vocal cord protection. The system provides Free-run EMG, Intermittent Triggered EMG, and Continuous Triggered EMG, allowing for monitoring of surgeries during Thyroid related cases.
● MEP (Motor Evoked Potential) Assessment
Safeguard facial nerve integrity. Designed for motor function evaluation, this module gives surgeons the confidence to navigate complex anatomical structures while minimizing the risk of post-operative deficits.
● NPC (Nerve Proximity Caution) Tool
Streamline the process of nerve detection. This semi-automated feature confirms the presence of nearby nerves and identifies the minimum effective stimulation intensity. It empowers surgeons to protect neural pathways with precision and minimal tissue trauma.
Technical Specifications
| Measurement range | 20μV-70000μV,error ≤±10% |
| Bandwidth | 0.4Hz-7kHz |
| CMRR | ≥120dB |
| Input Impedance | ≥200MΩ |
| Noise Level | ≤0.7μV RMS |
| MEP Stimulation Output | Intensity:0~1000V,0~1000mA, error ≤±10% Pulse Width:30~500μs, error ≤±10% |
| Regular Stimulation Output | Intensity:0~400V,0~100mA, error ≤±10% Frequency: 0.01~100Hz, error ≤±10% Pulse Width:25~1000μs, error ≤±10% |
| Low Level Stimulation Output | Intensity:0~8mA,step size 0.01mA, error ≤±10% Frequency: 0.1~30Hz, error ≤±10% Pulse Width:50~1000μs, error ≤±10% |
Advantage
In the delicate field of ENT surgery, how to accurately identify and protect nerves matters. Cynapse Lite equips surgeons and electrophysiologists with a sophisticated yet intuitive toolkit for intraoperative decision-making.
Clinically Proven: High-fidelity signal quality inherited from the flagship Cynapse platform.
Touchscreen Interface: Seamless and convenient control for rapid adjustments in the sterile field.
All-in-One ENT Solution: Unified monitoring for both facial and recurrent laryngeal nerves.
Cynapse Lite: Delivering a more complete, dependable, and safer approach to intraoperative nerve preservation.