Smart Intraoperative Nerve Monitoring Sysetm( SIOM )-The Intelligent Choice for ENT Monitoring

helps reduce the risk of nerve damage during various of types of surgery and identify the integrity of nerve function before the end of surgery through monitoring triggered EMG activities in multiple cranial and peripheral nerves. Especially applied in thyroid surgery, ENT, oral and maxillofacial surgery or simple spine surgery.

Appurtenance:
Description

(1)All-in-One Compact Design: Integrates 8 recording channels and 2 stimulation channels in a single device, ensuring straightforward setup and operation.
(2)Intelligent Auditory Guidance: Provides real-time auditory feedback (event, stimulus, and EMG sounds) to assist in nerve localization through variations in voice intensity.
(3)Real-Time Quality Control: Features  impedance testing and stimulus current measurement during surgery to maintain monitoring reliability.
(4)Adaptive Protocol Templates: Includes built-in standard and customized templates for quick adaptation to various ENT surgery types without complex configuration.
(5)Comprehensive Reporting Tools: Enables waveform annotations during testing or playback for clearer and more detailed output reports.
(6)Surgery-Specific Defaults: Automatically loads preset parameters tailored to the surgery type, with full flexibility for manual optimization.

IOM System(43e67d3e4f).png 1.120(f9df74b81c).png 1.118(8b61549b4f).png
1.120.png 1.119.png 1.118.png
1.160(a48892e887).png 1.135(37925bb5da).png 1.134(6578a5b7fc).png
Technical Specifications

Measurement range

20μV-70000μV, error within±10%

Bandwidth

0.4Hz-7KHz

CMRR

≥110dB

Input Impedance

≥2MΩ

Noise Level

≤0.7μV RMS

Current intensity output range

0mA-30mA, error within±10%

Stimulus frequency

1Hz-30Hz, error within±10%

Stimulus pulse width

50μs,100μs,150μs,200μs or 250μs, error within±10%

Advantage

Advantage 1: All-in-One Integration Simplifies Complex Setups

Market Challenge: Traditional IONM setups in ENT surgeries require connecting multiple separate devices and managing complex cabling, significantly increasing preparation time and introducing potential points of failure in the crowded surgical field.
NCC Solution: The Smart IONM integrates 8 recording channels and 2 stimulation channels into a single, compact unit. This all-in-one design eliminates the need for multiple modules and extensive cabling, enabling rapid deployment and straightforward operation.

Advantage 2: Intelligent Auditory Guidance Enhances Surgical Precision

Market Challenge: During critical dissection near nerves like the facial nerve, surgeons often lack immediate, intuitive feedback about the proximity to neural structures, relying solely on visual waveform interpretation which can divert attention from the surgical field.
NCC Solution: The system provides distinct real-time auditory feedback for different events. The varying intensity of these sounds offers an immediate, intuitive cue about the relative position of surgical instruments to nerves, enabling faster and more confident nerve identification and preservation without requiring the surgeon to constantly view the monitor.

Advantage 3: Automated Quality Control Ensures Monitoring Reliability

Market Challenge: Maintaining signal quality and stimulation integrity throughout a surgery requires constant manual verification. Signal degradation or inaccurate stimulation may go unnoticed, potentially compromising the reliability of monitoring results and surgical decisions.
NCC Solution: With real-time impedance testing and stimulus current measurement, the system automatically verifies the integrity of the entire monitoring pathway. This proactive quality control ensures that the physiological data presented is trustworthy and the stimulation is delivered as intended.

Advantage 4: Adaptive Templates Accelerate Workflow Efficiency

Market Challenge: Configuring monitoring parameters for different ENT procedures is time-consuming and requires specialized knowledge. Inconsistent settings across cases or staff can lead to variable data quality and increased setup time.
NCC Solution: Featuring built-in standard and customized templates, the system allows instant configuration for various surgery types. Preset parameters tailored to specific procedures are automatically loaded, drastically reducing setup time and minimizing manual configuration errors while retaining full flexibility for case-specific optimization.

Service & Support: Global Technical Assurance

Our commitment to your NCC system's complete lifecycle is guaranteed by our robust support framework, designed to ensure maximum uptime and operational excellence.
Click below for specific service programs, training schedules, and technical documentation.

Partner Programs

Distributor Support Program: Focused program designed to provide comprehensive sales and technical resources to our global partners.
Global Initiatives: Dedicated resources to support global market implementation, including expert surgical demonstrations and technical specialist training.
OEM/ODM Partner: NCC Medical is a trusted partner for customized neurophysiology solutions, offering specialized OEM and ODM services.

Click below for specific service programs, training schedules, and technical documentation.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Your Role
Company Name
Message
0/1000

Get More Information

Related Consumables
Related Consumables
Clinical Solutions
Clinical Solutions
Service & Training
Service & Training

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Your Role
Company Name
Message
0/1000

Copyright © NCC Medical Co., Ltd.  -  Privacy policy